1999 / 2000 Field Season
Updated: 30-October-1999
Contact: Joe Kujawski kujawsjo@mcmurdo.gov
Service items for AGO-1:
STATION:
Perform station upgrade (see CAGOSYS documentation)
DAU
Replace the NVRAM with a new NVRAM.
Shutoff valve
Replace batteries in the shutoff valve.
TEG
Set pressure to 3.5 PSI. Set each burner temperature to 260-300°C.
Set the indoor temperature to 15-20°C.
EXPERIMENTS:
Lucent Fluxgate magnetometer
See service instructions for normal servicing. Verify H axis.
There should be no offset. Verify that the operating range switch is set to 10^3 nT.
Tohuku searchcoil magnetometer
Upgrade per CAGOULFM. Verify that the experiment is functioning.
Stanford VLF receiver
Upgrade per CAGOELFM. Verify operation.
Perform the calibration procedure if the equipment is available. Install new batteries.
University of Maryland Riometer
Install the new filter module in the Riometer vault. Install signal attenuators in riometer vault.
Verify operation of the experiment over a 24-hour period.
Verify that the data does not seem to clip at a lower that expected value.
Dartmouth LF/MF/HF receiver
Collect data and verify the operation of the experiment.
Allsky camera
Perform allsky camera modification (CAGOALLM). Install new batteries.
Install new EPROM. If calibration flashlight is available, use it to capture a few images.
If not, capture blank images (with the camera completely covered).
Verify the locations of the calibration squares and the photodiode levels. Install new batteries.
Anubis Seismic
Install the Anubis seismic experiment per the experimenters documentation.
NASA LIDAR
Remove experiment from station and return it to Jonathan Rall in McMurdo or South Pole.
Service items for AGO-2:
STATION:
Perform station upgrade (see CAGOSYS documentation). Raise the station if necessary.
DAU
Replace the NVRAM with a new NVRAM.
Shutoff valve
Replace batteries in the shutoff valve.
TEG
Set pressure to 3.5 PSI. Set each burner temperature to 260-300°C. Set the indoor temperature to 15-20°C.
EXPERIMENTS:
Lucent Fluxgate magnetometer
See service instructions for normal servicing. Verify H axis.
There should be an offset of +500nT from the null.
Verify that the operating range switch is set to 10^3 nT.
Determine the problem with the bias field selector switch and fix the problem (see instructions).
Tohuku searchcoil magnetometer
Upgrade per CAGOULFM. Verify that the experiment is functioning.
Stanford VLF receiver
Upgrade per CAGOELFM. Verify operation. Perform the calibration procedure if the equipment is available.
Install new batteries.
University of Maryland Riometer
Install the new filter module in the Riometer vault. Verify operation of the experiment over a 24-hour period.
Verify that the data does not seem to clip at a lower that expected value.
Dartmouth LF/MF/HF receiver
Collect data and verify the operation of the experiment.
Allsky camera
Perform allsky camera modification (CAGOALLM). Install new batteries. Install new EPROM.
If calibration flashlight is available, use it to capture a few images.
If not, capture blank images (with the camera completely covered).
Verify the locations of the calibration squares and the photodiode levels. Install new batteries.
Anubis Seismic
Change the existing installation to match the other new installations.
All that should be necessary is to remove the electronics systems and verify the operation of the equipment.
Service items for AGO-3:
STATION:
Perform station upgrade (see CAGOSYS documentation).
DAU
Replace the NVRAM with a new NVRAM.
Shutoff valve
Replace batteries in the shutoff valve.
TEG
Set pressure to 3.5 PSI. Set each burner temperature to 260-300°C. Set the indoor temperature to 15-20°C.
EXPERIMENTS:
Lucent Fluxgate magnetometer
See service instructions for normal servicing. Verify H axis. There should be an offset of +500nT from the null. Verify that the operating range switch is set to 10^3 nT.
Tohuku searchcoil magnetometer
Upgrade per CAGOULFM. Verify that the experiment is functioning.
Stanford VLF receiver
Upgrade per CAGOELFM. Verify operation. Perform the calibration procedure if the equipment is available. Install new batteries.
University of Maryland Riometer
Install the new filter module in the Riometer vault.
Verify operation of the experiment over a 24-hour period. Verify that the data does not seem to clip at a lower that expected value.
Dartmouth LF/MF/HF receiver
Collect data and verify the operation of the experiment.
Allsky camera
Perform allsky camera modification (CAGOALLM). Install new batteries.
Install new EPROM. If calibration flashlight is available, use it to capture a few images. If not, capture blank images (with the camera completely covered). Verify the locations of the calibration squares and the photodiode levels. Install new batteries.
Anubis Seismic
Install the Anubis seismic experiment per the experimenters documentation.
Service items for AGO-4:
STATION:
Perform station upgrade (see CAGOSYS documentation
DAU
Replace the NVRAM with a new NVRAM.
Shutoff valve
Replace batteries in the shutoff valve.
TEG
Set pressure to 3.5 PSI. Set each burner temperature to 260-300°C. Set the indoor temperature to 15-20°C.
EXPERIMENTS:
Lucent Fluxgate magnetometer
See service instructions for normal servicing. Verify H axis. There should be no offset from the null.
Verify that the operating range switch is set to 10^3 nT.
Tohuku searchcoil magnetometer
Upgrade per CAGOULFM. Verify that the experiment is functioning.
Stanford VLF receiver
Upgrade per CAGOELFM. Verify operation.
Perform the calibration procedure if the equipment is available. Install new batteries.
University of Maryland Riometer
Install the new filter module in the Riometer vault. Replace riometer phasing system (vault electronics).
Verify operation of the experiment over a 24-hour period. Verify that the data does not seem to clip at a lower that expected value.
Dartmouth LF/MF/HF receiver
Collect data and verify the operation of the experiment.
Allsky camera
Perform allsky camera modification (CAGOALLM). Install new batteries.
Install new EPROM. If calibration flashlight is available, use it to capture a few images.
If not, capture blank images (with the camera completely covered).
Verify the locations of the calibration squares and the photodiode levels. Install new batteries.
Anubis Seismic
Install the Anubis seismic experiment per the experimenters documentation.
Service items for AGO-5:
STATION:
Perform station upgrade (see CAGOSYS documentation).
DAU
Replace the NVRAM with a new NVRAM.
Shutoff valve
Replace batteries in the shutoff valve.
TEG
Set pressure to 3.5 PSI. Set each burner temperature to 260-300°C. Set the indoor temperature to 15-20°C.
EXPERIMENTS:
Lucent Fluxgate magnetometer
See service instructions for normal servicing. Verify H axis.
There should be no offset from the null. Verify that the operating range switch is set to 10^3 nT.
Tohuku searchcoil magnetometer
Upgrade per CAGOULFM. Verify that the experiment is functioning.
Stanford VLF receiver
Upgrade per CAGOELFM. Verify operation. Perform the calibration procedure if the equipment is available. Install new batteries.
University of Maryland Riometer
Install the new filter module in the Riometer vault. Verify operation of the experiment over a 24-hour period. Verify that the data does not seem to clip at a lower that expected value.
Dartmouth LF/MF/HF receiver
Collect data and verify the operation of the experiment.
Allsky camera
Perform allsky camera modification (CAGOALLM). Install new batteries. Install new EPROM.
If calibration flashlight is available, use it to capture a few images. If not, capture blank images (with the camera completely covered).
Verify the locations of the calibration squares and the photodiode levels. Install new batteries.
Service items for AGO-6:
STATION:
Perform station upgrade (see CAGOSYS documentation). Raise station.
DAU
Replace the NVRAM with a new NVRAM. Determine problem with serial connection on the channel in which the Allsky camera is connected. There also may be a problem with the serial connection to the DCU. Investigate this possible problem.
Shutoff valve
Replace batteries in the shutoff valve.
TEG
Set pressure to 3.5 PSI. Set each burner temperature to 260-300°C. Set the indoor temperature to 15-20°C.
EXPERIMENTS:
Lucent Fluxgate magnetometer
Relocate the magnetometer vault per experimenter instructions. Verify H axis. There should be no offset from the null.
Verify that the operating range switch is set to 10^3 nT.
Tohuku searchcoil magnetometer
Upgrade per CAGOULFM. Verify that the experiment is functioning.
University of Maryland Riometer
Install the new filter module in the Riometer vault. Verify operation of the experiment over a 24-hour period.
Verify that the data does not seem to clip at a lower that expected value.
Dartmouth LF/MF/HF receiver
Collect data and verify the operation of the experiment.
Allsky camera
Install new electronics box. Perform allsky camera modification (CAGOALLM). Install new batteries. Install new EPROM. If calibration flashlight is available, use it to capture a few images. If not, capture blank images (with the camera completely covered). Verify the locations of the calibration squares and the photodiode levels. Install new batteries.